Dokumentation
Ose_directory e-shot
2704 Visninger •Checkline II maintenance manual
3078 Visninger •Chemsplash Pro WD40 Test
2424 Visninger •Ergonomi 2006
2997 Visninger •Ose_directory Suspension harness
2740 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3442 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3219 Visninger •VISOR Installation steps
3995 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2983 Visninger •Hearing protection 3M
2539 Visninger •Statistik for arbejdsmiljø 2014
2999 Visninger •LOTO_GuideBook_Europe_English
2541 Visninger •Remote area lighting system
2300 Visninger •Isol8 - The Ultimate Absorbent for Spills
2314 Visninger •Magazine Arbejdsmiljø - november 2012
2492 Visninger •KEE_DOME_MINI
2403 Visninger •TDS Speedglas 9100
2579 Visninger •The Pocketbook of Lean Visuals
2574 Visninger •Instructional video Sign holder
1863 Visninger •PREMARK installation manual
2535 Visninger •D-S CSR Håndbog
17047 Visninger •Find handskestørrelse - størrelsesguide for handsker
10038 Visninger •3M jupiter manual
6142 Visninger •9100 Manual
5093 Visninger •D-S 70 års om os brochure
4746 Visninger •EN 388 nye mærkninger forklaring
4732 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4671 Visninger •Faldsikring flyer
4312 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4036 Visninger •VISOR Installation steps
3995 Visninger •Guide til valg af åndedrætsværn
3578 Visninger •TR-300 Bruger manual
3544 Visninger •VARMEX 2000 Fordele
3533 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3442 Visninger •3M TR 300 PAPR training video
3422 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3219 Visninger •Procedure for iklædning af engangsbeklædning
3182 Visninger •3020 Solcreme SPF 30 datablad
3155 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3142 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3111 Visninger •Smart P Sensitron Brochure
Visninger | |
---|---|
373 | Totale visninger |
0 | Medlemmer visninger |
373 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
2. SENSITRON A Halma Company DS4847 SMART P-2 Datasheet (EN) P. 2/4 The SMART P-2 gas detector is designed to be installed in car parks and simultaneously detect CO and NO2 gases or CO and petrol vapors. It is compliant with the EN 50545-1 standard, which defines the requirements for the detection of CO and NO2 in car parks and tunnels. For the detection of toxic gases (CO and NO2) the electrochemical cell is used and is housed in the polycarbonate head. The catalytic sensor is used to detect petrol vapors, which guarantees excellent linearity up to 100% LFL. This sensor is placed in an aluminum head, which can be remoted with a maxiumum distance of 1.5m. The EN 50545-1 standard describes the values of the alarm thresholds for CO and NO2, moreover the activation of the alarms is a function of the time- weighted average of the detected gas concentration. The SMART P-2 has a 12-24 Vdc power supply and an RS485 digital signal output. The detectors are housed in polycarbonate enclosures complete with two M20 cable glands. Sensor Application Car parks Sensing element Catalytic sensor for petrol vapours Electrochemical cell for CO and NO 2 Predicted sensor lifetime Catalytic: 4 / 5 years EC: 2 / 3 years Gas detected Petrol vapours, CO, NO 2 Fullscale Petrol vapours: 0 - 100% LFL CO: 0 - 300 ppm, NO 2 : 0 - 30 ppm Electrical data Power supply 12-24 Vdc Output RS485 serial output Absorption S2400CO-ND: 32 mA at 24 Vdc S2400CO-VB: 63 mA at 24 Vdc Optical indications - Acoustic indications - Hall effect sensor - Environmental conditions Storage temperature 0 / +20°C up to six months Operating temperature -20 / +50°C Opertaing humidity 15 /90 %RH
1. SMART P-2 Gas detection in car parks Datasheet SENSITRON A Halma Company SMART P-2 Datasheet DS4847 SENSITRON S.R.L. - All rights reserved - www. sensitron.it DS4847 Rev.1 24/03/2023 Sensitron S.r.l., Viale della Repubblica 48, Cornaredo (MI) sales@sensitron.it TEL. +390293548155 FAX. +390293548089
4. Contatti/Contacts Viale della Repubblica, 48 20007 Cornaredo (MI) – ITALY +39 0293548155 sales@sensitron.it sensitron.it Sensitron S.r.l. DS4847 Sensitron S.r.l., Viale della Repubblica 48, Cornaredo (MI) sales@sensitron.it TEL. +390293548155 FAX. +390293548089 SENSITRON A Halma Company SMART P-2 Datasheet DS4847 SENSITRON S.R.L. - All rights reserved - www. sensitron.it
3. SENSITRON A Halma Company DS4847 SMART P-2 Datasheet (EN) P. 3/4 Compliance EMC EN 50270:2015 Car park standard EN 50545-1:2011 + A1:2016 Product codes S2400CO-ND CO (0-300 ppm) and NO 2 (0-30 ppm) gas detector S2400CO-VB CO (0-300 ppm) petrol vapours (0-100% LFL) gas detector Mechanical drawings Catalytic sensor head It can be a remote head 100 mm 54 mm 105,8 mm 105,8 mm 27 mm 17 mm 27 mm 17 mm External case Material Enclosure: Polycarbonate Sensor head: Polycarbonate or aluminum Dimensions Box: 100 x 100 x 52 mm Cover: 105.8 x 105.8 x 7.8 mm Weight 250 g Cable entries 2 x M20 IP grade IP55 Remote head cable length 1.5 m 27 mm 35 mm 48 mm
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.