3. System Components Dräger X-act ® 5000 Basic | 03 ST-36-2001 Dräger Short-Term Tubes Tried and tested a million times: Worldwide, the Dräger Short-Term Tubes have proven to be a very cost-effective and reliable method for the measurement of gases. Decreasing occupational exposure values, special customer requirements and new legal regulations made it necessary to develop even more sensitive Dräger-Tubes. 2-925-91 Dräger Sampling Tubes and Systems The Dräger Sampling Tubes and Systems are very reliable in use even with complex compounds and mixtures of substances. Accessories ST-1990-2005 Dräger TO 7000 By using the tube opener Dräger TO 7000, conventional Short-Term Tubes as well as Ampoule and Double Tubes can be opened with only simple movements and no jagged edges are left behind.

5. Accessories Dräger X-act ® 5000 Basic | 05 D-13067-2010 Vehicle exhaust probe For measuring exhaust gases. ST-1694-2003 Fumigation case Determines quickly and easily whether a container is fumigated. Case for self-equipment. Related Products D-19328-2009 Dräger accuro Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.

1. Dräger X-act ® 5000 Basic Pump for Gas Detection Tubes The automatic tube pump Dräger X-act ® 5000 Basic is the all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and systems. Ease of operation and a high degree of reliability compliment the measurement and sampling of gases, vapors and aerosols. D-0185-2019 Connection with Tube Swivel Display – Segment Display – Matrix Display Battery Pack (Drawer) Flashing Lights Green: End of measurement Red: ERROR

2. Benefits 02 | Dräger X-act ® 5000 Basic Automatic tube pump ‒ ideal for a high number of strokes ‒ display for clear readability of results ‒ can be used in explosive areas Versatile and robust The automatic tube pump is compatible with Dräger short-term tubes as well as sampling tubes and systems. The robust housing supports the use of the pump to perform the daily measuring tasks under tough conditions. The ex-approved Dräger X-act ® 5000 Basic can be used for confined space applications and in explosive gas atmospheres. New pump concept The key principle is the ability to provide the required flow characteristics of the short-term tubes, while also providing the option to be used with sampling tubes and Systems requiring constant flow. Compared to the Dräger accuro hand pump, this new concept reduces the average measurement time of the short-term tubes in case of a high number of strokes. The internal pump is also designed to use extension hoses up to a length of 30 meters (98 ft.). Simplicity of operation The handling of gases, vapors and aerosols has never been easier. The automatic tube pump directs the air to be measured through the appropriate Dräger-Tubes effortlessly. It is comfortably carried with one hand or using the shoulder strap and is easily operated, even wearing protective gloves. A simple and intuitive menu structure provides the user efficient operation with just a few button presses. Using the password-protected menu repetitive operating modes can be set. Measurement in technical gases To evaluate measurements in technical gases, the properties of the technical gas must be taken into consideration. Technical gases have a different viscosity than ambient air. Therefore, the flow of the pump must be set accordingly. Following the operating steps in the mode „Measurement in Technical Gases“, the Dräger X-act 5000 Basic will automatically be adjusted to the required flow parameter and the measurement result can be read directly. Direct settings for sampling Depending on the sampling tubes or systems, the required parameters for the test can be set directly, without the need for an external flowmeter. The X-act 5000 Basic automatically adjusts the flowrate. After setting the sampling time the pump can immediately be started. At the end of the measurement the pump will stop automatically. The set data, the elapsed time and the pumped volume will be indicated on the display.

4. Accessories 04 | Dräger X-act ® 5000 Basic D-12076-2010 Dräger SO<sub>3</sub> Filter For retaining possible SO 3 , which can occur during measurement with Short-term Tubes. ST-14319-2008 Dräger X-act 5000 extension hoses For use in hard-to-access locations such as shafts. Available in the following sizes: ‒ 1 m ‒ 3 m ‒ 10 m ‒ 15 m ‒ 30 m D-13066-2010 Hot air probe Enables the measurement of extremely hot gases, e.g. in combustion plants. D-13069-2010 Bar probe 400 Is used for clearance measurements in containers.

8. Notes 08 | Dräger X-act ® 5000 Basic Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53–55 23558 Lübeck, Germany www.draeger.com REGION DACH Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA PACIFIC Draeger Singapore Pte. Ltd. 61 Science Park Road The Galen #04-01 Singapore 117525 Tel: +65 6872 9288 Fax: +65 6259 0398 asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Draeger Panamá Comercial S. de R.L. 59 East Street, Nuevo Paitilla, House 31, San Francisco Town Panama City, Panama Tel +507 377-9100 / Fax -9130 servicioalcliente@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact 90 46 996 | 20.02-7 | HQ | PP | Subject to modifications | © 2020 Drägerwerk AG & Co. KGaA

7. Ordering Information Dräger X-act ® 5000 Basic | 07 Power packs Rechargeable Battery NiMH, T4 45 23 520 Charging accessories Wall-Wart Charger 100 – 240 VAC (worldwide) 45 23 545 Car Charger 12 / 24 V 45 23 511 Accessories Extension hose, Dräger accuro & Dräger X-act ® 5000, 1 m, incl. adapter for Simultaneous Test Set 64 00 561 Extension hose, Dräger accuro & Dräger X-act ® 5000, 3 m, incl. adapter for tubes, adapter for hose in a carrying box 64 00 077 Extension hose, Dräger accuro & Dräger X-act ® 5000, 10 m, incl. adapter for tubes, adapter for hose 64 00 078 Extension hose, Dräger accuro & Dräger X-act ® 5000, 15 m, incl. adapter for tubes, adapter for hose 64 00 079 Extension hose, Dräger X-act ® 5000, 30 m, incl. adapter for tubes, adapter for hose 64 01 175 SO 3 Filter Replacement 81 03 525

6. Technical Data 06 | Dräger X-act ® 5000 Basic Operation Short-term measurements using Dräger short-term tubes Number of strokes Stroke volume adjustable, 1 to 199 strokes 100 mL Flow rate range 0.1 to 2.0 L/min Resolution 0.1 to 1.0 L/min: 0.1 L/min ± 10 % Resolution 1.0 to 2.0 L/min: 0.2 L/min ± 10 % Sample taking Sampling time adjustable, up to 12 hours, depending on flow rate Resolution in steps of 15 minutes (default) or 1 minute Display two parts: segment and matrix Menu languages Danish, Dutch, English, Finnish, French, German, Italian, Norwegian, Polish, Spanish, Swedish Use of extension hose up to 30 meter (98 ft.) Dimensions (H x W x D) approx. 175 x 230 x 108 mm (7“ x 9“ x 4.25“) Weight (without battery pack) approx. 1.6 kg (3.5 lbs) Ambient Conditions Temperature during storage - 20 to 55 °C (- 4 to 131 °F) Temperature during operation 5 to 40 °C (41 to 104 °F) Humidity 0 to 95 % r. h., non-condensing Pressure 700 to 1,300 hPa (10.2 to 18.9 psi) Power Packs Rechargeable Battery NiMH, T4 7.2 V, 1,500 mAh (charging time < 4 hours) Battery capacity at 25 °C (77 °F) Dräger short-term tubes: >1,000 strokes Sample taking: up to 12 hours, depending on adjusted flow rate Approvals ATEX Ex ia IIC T4 Ga Ex ia I Ma I M1 / II 1G MED Steering Wheel approval 96/98 EC cUL Class I, Div. 1, Group A, B, C, D Class II, Div. 1, Group F, G 5 °C ≤ Ta ≤ + 40 °C Temp. Code T4 Ex ia IECEx Ex ia I Ma Ex ia IIC T4 Ga CE-mark according to 2014/30/EU, 2014/34/EU and 2011/65/EU 1 Subject to alteration Ordering Information Dräger X-act ® 5000 Basic Order code Dräger X-act ® 5000 Basic with shoulder strap without power supply 37 07 674