Dokumentation
Ose_directory e-shot
2727 Visninger •Checkline II maintenance manual
3096 Visninger •Chemsplash Pro WD40 Test
2445 Visninger •Ergonomi 2006
3024 Visninger •Ose_directory Suspension harness
2758 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3466 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3246 Visninger •VISOR Installation steps
4012 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
3004 Visninger •Hearing protection 3M
2558 Visninger •Statistik for arbejdsmiljø 2014
3026 Visninger •LOTO_GuideBook_Europe_English
2566 Visninger •Remote area lighting system
2325 Visninger •Isol8 - The Ultimate Absorbent for Spills
2330 Visninger •Magazine Arbejdsmiljø - november 2012
2509 Visninger •KEE_DOME_MINI
2427 Visninger •TDS Speedglas 9100
2601 Visninger •The Pocketbook of Lean Visuals
2588 Visninger •Instructional video Sign holder
1882 Visninger •PREMARK installation manual
2560 Visninger •D-S CSR Håndbog
17133 Visninger •Find handskestørrelse - størrelsesguide for handsker
10102 Visninger •3M jupiter manual
6193 Visninger •9100 Manual
5152 Visninger •D-S 70 års om os brochure
4797 Visninger •EN 388 nye mærkninger forklaring
4758 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4702 Visninger •Faldsikring flyer
4399 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4071 Visninger •VISOR Installation steps
4012 Visninger •Guide til valg af åndedrætsværn
3607 Visninger •TR-300 Bruger manual
3572 Visninger •VARMEX 2000 Fordele
3564 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3466 Visninger •3M TR 300 PAPR training video
3462 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3246 Visninger •Procedure for iklædning af engangsbeklædning
3204 Visninger •3020 Solcreme SPF 30 datablad
3170 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3157 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3126 Visninger •Q7946A Revision 0 EN352-9
Visninger | |
---|---|
233 | Totale visninger |
0 | Medlemmer visninger |
233 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
2. PAGE 2 OF 2 T able 2. Mean in ear noise levels using p50_f dB FS p50_f dB FS Mean (dBA) SD √Sum of squares Mean + √SS (dBA) - 35 66.8 0.3 3.0 69.8 - 30 66.8 0.3 3.0 69.8 - 25 68.5 0.3 3.0 71.5 - 20 68.9 0.2 3.0 71.9 - 15 69.3 0.2 3.0 72.3 - 10 69.6 0.2 3.0 72.6 Michael & Associates is accredited by the National Institute of Standards and Technology (NIST) National Laboratory Accreditation Program (NVLAP) for tests performed according to ANSI S3.19 - 1974, ANSI S12.6 - 2016, AS/NZ S1270:2002 and EN352 parts 1 - 10. These accreditation criteria encompass the requirements of international standard ISO 17025. This report may only be reproduced or transmitted electronically in its entirety. This report shall not be used to claim product approval, certifica tion or endorsement by NIST, NVLAP or by any agency of the U.S. Government. All measurement equipment are calibrated with instrumentation traceable to the NIST. Accreditation documentation can be viewed at www.michaelassociates.com/data/documents/NVLAP - 2023.pdf . Kevin Michael, Ph.D. President R² = 0.9022 50 55 60 65 70 75 80 85 -40 -35 -30 -25 -20 -15 -10 -5 0 dBA p50_f ( dB FS) Bluetooth transmission linearity check and visual reference to 82 dBA threshold limit Mean + √SS (dBA) Exposure Threshold
1. PAGE 1 OF 2 Test Report ID: Q 7 946 A Revision 0 Opsmen Tech Co., Ltd. Room 601, Building A, No.94 Liwan Road, Liwan District, Guangzhou, China Date of report: 1/ 3 1 /2 3 Date of sample receipt: 1 1 / 22 /22 Dates of testing: 1/ 30 /2 3 Technician: Sandar Bregg Table 1. Test Result Standard Maximum Output & usage time EN352 - 9 :2020 The maximum output level of 7 2 .6 dBA was less than 82 dBA , the usage time is >8 hours Acoustic testing was performed on M20/ M20T electronic earplugs according to EN352 - 9 :2020 for Bluetooth transmission ( Test ID Q7 946 A ). For the EN352 - 9 :2020 testing, a G.R.A.S. 45CB fixture was tested on each of the four samples twice for a total of eight measurements or 16 ears. The mean, standard deviation, and square root of the standard deviation’s sum of squares at each of the noise levels were calculated and presented in Table 1. Individual data is presented in the appendix. Noise levels tested ranged between - 35 dB FS to - 10 d B FS in 5 dB increments. For all tests, t he test signal was a simulated female speech according to ITU - T P50_F:1999 and volume controls were set to maximum . The maximum output level of 7 2 .6 dBA did not exceed the 82 dBA threshold limit and passed this test. 2766 W. College Ave Suite 1 State Colleg e, PA 16801 814 - 234 - 7042 phone 814 - 235 - 1381 fax Email: Kevin@michaelassociates.com URL: www.michaelassociates.com Figure 1 . M20/ M20T electronic earplugs
3. PAGE A - 1 Table 3 . Individual in ear noise levels in 5 dB increments using p50_f dB FS Device / Trial Side of head p50_f (dB FS) - 35 - 30 - 25 - 20 - 15 - 10 DFE Correct individual in ear noise levels (dBA) 1/A Left 66.8 66.8 68.6 68.9 69.1 69.4 Right 66.7 66.7 68.5 68.7 68.9 69.3 1/B Left 66.9 66.8 68.6 68.7 69.2 69.6 Right 67.0 66.9 68.7 68.9 69.4 69.8 2/A Left 66.7 66.6 68.2 68.5 69.1 69.2 Right 67.3 67.2 68.8 69.1 69.6 69.8 2/B Left 66.8 67.0 68.5 69.1 69.4 69.5 Right 66.8 67.0 68.4 69.1 69.5 69.6 3/A Left 66.9 67.0 68.7 69.0 69.4 69.5 Right 67.0 67.1 68.8 69.1 69.5 69.6 3/B Left 66.9 66.8 68.5 69.3 69.6 69.9 Right 66.4 66.3 68.1 68.9 69.3 69.6 4/A Left 66.5 66.5 68.2 68.9 69.2 69.5 Right 66.6 66.6 68.3 69.0 69.3 69.6 4/B Left 67.0 67.2 69.0 69.2 69.7 70.1 Right 66.3 66.6 68.3 68.6 69.2 69.6
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.